MICROMASTER 411 and COMBIMASTER 411 – Options
Variable-speed Drives for Decentralised Tasks
Software and Operator Control
|
Basic Operator Panel (BOP)
With the BOP, individual parameter settings can be made.
Values and units are shown on a 5-digit display.
A BOP can be used for several inverters.
It is mounted in the operator panel mounting kit,
for connection to the external communication interface of the inverter.
|
 |
|
Advanced Operator Panel (AOP) for MICROMASTER 411/ COMBIMASTER 411
With the BOP, individual parameter settings can be made.
Values and units are shown on a 5-digit display.
A BOP can be used for several inverters.
It is mounted in the operator panel mounting kit,
for connection to the external communication interface of the inverter.
|
 |
Commissioning Tools
- STARTER is start-up software for guided commissioning for MICROMASTER frequency inverters under Windows NT/2000. Parameter lists can be read out, altered, stored, entered and printed.
- DriveMonitor is start-up software for list-oriented parameterization of frequency inverters. This program can run under Windows 95/ 98/NT/2000/XP Professional.
Both programs are part of the Docu-CD supplied with each unit.
Communication Modules
|
PROFIBUS Module
PROFIBUS controlled operation is possible up to 12 Mbaud/s.
The PROFIBUS module can be powered from an external 24 V
supply so that the bus is active when the power is removed from the inverter.
The PROFIBUS module in the form of a separate module can be screwed
onto the case of the MICROMASTER 411/COMBIMASTER 411.
|
 |
|
AS Interface Module
This module enables the COMBIMASTER 411/MICROMASTER 411
inverter to communicate as a slave in an AS Interface
(actuator-sensor interface) communications network.
In a standard AS Interface system,
up to 31 slaves can be connected,
whereby each slave has up to 4 inputs and up to 4 outputs.
The module uses an external housing.
|
 |
|
ECOFAST PROFIBUS Module
This module enables the ECOFAST variants
of the COMBIMASTER 411 and MICROMASTER 411
inverters to communicate in a PROFIBUS
communications network. The transmission speed is 12 mbps.
The module also permits connection to three external
inputs (2 digital and 1 analog) and one digital
output via M12 connector. The ECOFAST PROFIBUS
module is accommodated in an external housing.
|
 |
|
ECOFAST Options (Especially for Addressing Connectors)
The ECOFAST PROFIBUS module has an addressing socket so
that the PROFIBUS address can be set with the
PROFIBUS addressing connector
(Order No.: 6ES7194-1KB00-0XA0),
which is available as an option.
|
 |
|
DeviceNet Module
This module enables the COMBIMASTER 411/MICROMASTER 411
inverters to communicate as nodes in a DeviceNet communications network.
The DeviceNet module allows transmission speeds of
125, 250 and 500 kbps. The module uses an external housing.
|
 |
Brake Function Modules
|
EM Module (Electromechanical Brake Control Module)
This module controls an electromechanical brake mounted on the motor.
The module is for mounting on the case of the MICROMASTER 411/ COMBIMASTER 411.
For more information on the motor brake, see Catalog M11 "Technical Explanations", "Brakes".
|
 |
|
REM Module (Rheostatic Brake and Control Module for Electromechanical Brake)
This module contains a brake chopper with
brake resistor and controls an external electromechanical
motor brake. The module is enclosed in an external
housing with the same degree of protection as the product series
|
 |
|